Load image into Gallery viewer, Bitmain Antminer S21 200T 3500W S21 Hyd 335T 5360W Bitcoin Miner| minerwinner
Load image into Gallery viewer, Bitmain Antminer S21 200T 3500W S21 Hyd 335T 5360W Bitcoin Miner| minerwinner
Load image into Gallery viewer, Bitmain Antminer S21 200T 3500W S21 Hyd 335T 5360W Bitcoin Miner| minerwinner
Load image into Gallery viewer, Bitmain Antminer S21 200T 3500W S21 Hyd 335T 5360W Bitcoin Miner| minerwinner
Load image into Gallery viewer, Bitmain Antminer S21 200T 3500W S21 Hyd 335T 5360W Bitcoin Miner| minerwinner
Load image into Gallery viewer, Bitmain Antminer S21 200T 3500W S21 Hyd 335T 5360W Bitcoin Miner| minerwinner

SKU: MW-BA-S21

Bitmain Antminer S21 200T 3500W S21 Hyd 335T 5360W Bitcoin Miner| minerwinner

Vendor MINERWINNER
Regular price $3,460.00
Sale price $3,460.00 Regular price $5,400.00
Sale Sold out
Unit price
/per 
Shipping calculated at checkout.
Model:
This is a pre order item. We will ship it when it comes in stock.

| Specifications


Product Glance  
Model S21
Algorithm | Cryptocurrency SHA256 | BTC/BCH/BSV
Hashrate, TH/s 200 
Power on wall @25°C, Watt 3500
Power efficiency on wall @25°C, J/TH 17.5
Detailed Characteristics  
Power Supply  
Power supply AC Input voltage, Volt(1-1) 220~277
Power supply AC Input Frequency Range, Hz 47~63
Power supply AC Input current, Amp(1-2) 20(1-3)
Hardware Configuration  
Networking connection mode RJ45 Ethernet 10/100M
Miner Size (Length*Width*Height, w/o package),mm(2-1) 400*195*290
Miner Size (Length*Width*Height, with package),mm 570*316*430
Net weight, kg(2-2) 15.4
Gross  weight, kg(2-2) 17.1
Environment Requirements  
Operation temperature,°C 0~45
Storage temperature,°C -40~85
Operation humidity(non-condensing) , RH 10~90%
Operation altitude, m(3-1) ≤2000

NOTE:

(1-1) Caution: Wrong input voltage may probably cause miner damaged

(1-2) Max condition: temperature 40°C, altitude 0m

(1-3) Two AC input wires, 10A per wire

(2-1) ​​​​Including PSU size

(2-2) Including PSU weight

(3-1) When the miner is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃ for every increase of 300m

| Specifications


Product Glance  
Model S21 Hyd.
Algorithm | Cryptocurrency SHA256 | BTC/BCH/BSV
Hashrate, TH/s(1-1) 335
Power on wall @35°C(1-2), Watt(1-1) 5360
Power efficiency on wall @35°C(1-2), J/TH(1-1) 16.0
Detailed Characteristics    
Power Supply    
Power supply AC Input voltage, Volt(2-1) 380~415V AC  
Power supply AC Input Frequency Range, Hz 50~60  
Power supply AC Input current, Amp(2-2) 12  
Hardware Configuration    
Networking connection mode RJ45 Ethernet 10/100M  
Miner Size (Length*Width*Height, w/o package),mm 339*163*207  
Miner Size (Length*Width*Height, with package),mm 570*316*430  
Net weight, kg 12.3  
Gross weight, kg 13.6  
Environment Requirements    
Inlet water temperature, °C

NEM(2-3)

HEM1(2-3)

HEM2(2-3)

35

45

50

Water flow, L/min 8.0~10.0
Water pressure bar ≤3.5
Working fluid(2-4) Deionized water/Pure water
Liquid PH 8.5~9.5
Diameter of water pipe connector, mm DN10
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%

NOTE:

(1-1) The Hashrate value, Power on wall, and Power efficiency on wall are all typical values, The actual Hashrate value fluctuates by 3%, and the actual Power on wall and Power efficiency on wall fluctuate by 5%.
(1-2) Inlet water temperature.
(2-1) Caution: Wrong input voltage may probably cause server damaged.
(2-2) Three-phase AC input, 10 A per wire.
(2-3) NEM: Normal Energy Mode; HEM: High Energy Mode.
(2-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.

Decsription

| Specifications


Product Glance  
Model S21
Algorithm | Cryptocurrency SHA256 | BTC/BCH/BSV
Hashrate, TH/s 200 
Power on wall @25°C, Watt 3500
Power efficiency on wall @25°C, J/TH 17.5
Detailed Characteristics  
Power Supply  
Power supply AC Input voltage, Volt(1-1) 220~277
Power supply AC Input Frequency Range, Hz 47~63
Power supply AC Input current, Amp(1-2) 20(1-3)
Hardware Configuration  
Networking connection mode RJ45 Ethernet 10/100M
Miner Size (Length*Width*Height, w/o package),mm(2-1) 400*195*290
Miner Size (Length*Width*Height, with package),mm 570*316*430
Net weight, kg(2-2) 15.4
Gross  weight, kg(2-2) 17.1
Environment Requirements  
Operation temperature,°C 0~45
Storage temperature,°C -40~85
Operation humidity(non-condensing) , RH 10~90%
Operation altitude, m(3-1) ≤2000

NOTE:

(1-1) Caution: Wrong input voltage may probably cause miner damaged

(1-2) Max condition: temperature 40°C, altitude 0m

(1-3) Two AC input wires, 10A per wire

(2-1) ​​​​Including PSU size

(2-2) Including PSU weight

(3-1) When the miner is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃ for every increase of 300m

| Specifications


Product Glance  
Model S21 Hyd.
Algorithm | Cryptocurrency SHA256 | BTC/BCH/BSV
Hashrate, TH/s(1-1) 335
Power on wall @35°C(1-2), Watt(1-1) 5360
Power efficiency on wall @35°C(1-2), J/TH(1-1) 16.0
Detailed Characteristics    
Power Supply    
Power supply AC Input voltage, Volt(2-1) 380~415V AC  
Power supply AC Input Frequency Range, Hz 50~60  
Power supply AC Input current, Amp(2-2) 12  
Hardware Configuration    
Networking connection mode RJ45 Ethernet 10/100M  
Miner Size (Length*Width*Height, w/o package),mm 339*163*207  
Miner Size (Length*Width*Height, with package),mm 570*316*430  
Net weight, kg 12.3  
Gross weight, kg 13.6  
Environment Requirements    
Inlet water temperature, °C

NEM(2-3)

HEM1(2-3)

HEM2(2-3)

35

45

50

Water flow, L/min 8.0~10.0
Water pressure bar ≤3.5
Working fluid(2-4) Deionized water/Pure water
Liquid PH 8.5~9.5
Diameter of water pipe connector, mm DN10
Storage temperature, °C -20~70
Operation humidity(non-condensing), RH 10~90%

NOTE:

(1-1) The Hashrate value, Power on wall, and Power efficiency on wall are all typical values, The actual Hashrate value fluctuates by 3%, and the actual Power on wall and Power efficiency on wall fluctuate by 5%.
(1-2) Inlet water temperature.
(2-1) Caution: Wrong input voltage may probably cause server damaged.
(2-2) Three-phase AC input, 10 A per wire.
(2-3) NEM: Normal Energy Mode; HEM: High Energy Mode.
(2-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.